AMC 300

3-phase Grid measurement inputs 2 x 3-phase(L1;L2;L3;N 400 VAC/690 VAC 1 x 3-phase (L1;L2;L3;N) 1A/5A Class 0.5 (Power) Class 0.2 (U; I) Altitude Up to 4000 m; refer to module specification for over 2000 m Analogue Inputs 0/24 VDC with wire break detection 0...10 V +/-10 V 0...20 mA 4...20 mA PT100 2-wire PT1000 2-wire Thermocouple(E;J;K;N;R;S;T) RMI


3-phase Grid measurement inputs 2 x 3-phase(L1;L2;L3;N 400 VAC/690 VAC 1 x 3-phase (L1;L2;L3;N) 1A/5A Class 0.5 (Power) Class 0.2 (U; I)
Altitude Up to 4000 m; refer to module specification for over 2000 m
Analogue Inputs 0/24 VDC with wire break detection 0...10 V +/-10 V 0...20 mA 4...20 mA PT100 2-wire PT1000 2-wire Thermocouple(E;J;K;N;R;S;T) RMI (0..4.5 kOhm)
Analogue Outputs +/-10V +/-25 mA 1..10V PWM (0...2500Hz)
Approvals CE; UL/ULC;DNV;BV
Communication Protocols PCM3.1 EtherCAT master OPC DA OPC UA Server CANOpen Master CANOpen Slave Modbus TCP Slave Modbus TCP Master HTTPS/WSS/JSON (CVI) J1939
Concept Base mount for increased stability
Connector type Connector w. screw
Cooling Passive
Depth (incl. connectors) 158
Digital Inputs 24 VDC (+/-36V...+/-8V) Frequency Counter (Up to 20kHz)
Digital Outputs 24 VDC DO Relay Outputs
EtherCAT ports 2 (via PSM3.1)
Ethernet 5 switched (managed) 100 Mbps
Ethernet ports 5 switched 100 Mbit/s
Expandable storage SD card slot
Fieldbusses Ethernet EtherCAT with cable redundancy CAN
Frequency 35 to 78 Hz
Hardware design life time no less than 10 years @ 40 °C
Height [mm] 168
Internal Storage 512 MB
IO modules Up to 6 per rack
Memory (RAM) 256 MB
Operating System DEIF In-house maintained Operating System (BSPv4) Real-time patched Linux® n-device web-based configuration Fail-safe system software start up with two OS images (active and fault-back) Power fail-safe; self-monitoring and error correcting file system Simplified update procedures (no special tools; same for OS and firmware)
Operating System (Cont) Secured Certificated based access by standard protocols User access management (Operator; Service and Administrator); rights and credentials Network configuration of the build-in 5 port switch (VLAN) IPv4 and IPv6 support Network Time protocol support as Client and Server Secured communication with certificated based authentication access by standard protocols Discover the device via hostname (mDNS services) Device backup and restore Secure boot (Chain-of-trust)
Operating Temperature -40 °C ... 70 °C
Persistent storage Via CmpApp to Internal flash
PLC runtime CODESYS V3 SP15 or later
Processor 400 MHz Power based CPU
Programming Available on request
Protection Class IP21
Real-time Clock(RTC)  
Relative humidity 97 % 55 °C condensation
Start up temperature -40 °C
Storage -40 °C ... 85 °C
Typical applications Trains Mobile Power generation Gen-set control Facility Building automation Marine Propulsion
USB Host 0
Vibrations (Bump) 20 g; 16 ms; half sine (IEC 60255-21-2 class 2)
Vibrations (Endurance) 10 to 150 Hz: 2 g (IEC 60255-21-1 class 2)
Vibrations (Operational) 3 to 8 Hz: 17 mm peak-peak 8 to 100 Hz: 4 g 100 to 500 Hz: 2 g
Vibrations (Response) 10 to 58.1 Hz: 0.15 mm peak-peak 58.1 to 150 Hz: 1 g ( IEC 60255-21-1 class 2)
Vibrations (Seismic) 3 to 8.15 Hz: 15 mm peak-peak 8.15 to 35 Hz: 2 g (IEC 60255-21-3 class 2)
Vibrations (Shock) 10 g; 11 ms; half sine (IEC 60255-21-2 Response class 2) 30 g; 11 ms; half sine (IEC 60255-21-2 Endurance class 2) 50 g; 11 ms; half sine (IEC 60068-2-27)
Width [mm] See datasheet

Whatsapp Support

Hello

How can help you ?